|
|
Technical Sheet for ASI 306
UNCURED: Type .........................................................................One-part, self-leveling RTVAppearance .................................................................Smooth, thick liquidSpecific Gravity ............................................................Clear 1.02; Colors 1.04Application Temperature Range .........................................-18°C to +50°C (0°F to +120°F)Cure Method .................................................................Neutral, non-corrosive, moisture cureSkin Over Time...............................................................40 minutesCure Time ....................................................................24 Hours (1/8" thickness)Slump/Sag ....................................................................FlowableCURED: at 25°C (77°F) and 50% R.M. for 7 days (1/8" thick)Durometer Hardness (Shore A) (ASTM D 2240) .........................25Tensile Strength (ASTM D 412) ............................................230 psi (1.6 MPa)Elongation at Break (ASTM D 412) .........................................400%Tear Resistance (ASTM D 624, Die B) ......................................6 ppi (4.6 kN/m)Temperature Range After Cure .............................................-57°C to +204°C (-70°F to +400°F)Shrink Factor...................................................................NilThermal Expansion Coefficient ..............................................9 x 10 -4 1/K0°C to 100°C (32°F to 212°F)Dielectric Strength (ASTM D 149) ............................................452 V/mil (173 KV/cm)Volume Resistivity(ASTM D257) ...............................................>2.19 x 1015 ohm/cmDissipationFactor(ASTMD150)..................................................0.00106at100Hz0.00022 at 10kHzDielectric Constant (ASTM D 150) .............................................71 at 100 Hz2.71 at 10 kHz
SAFETY PRECAUTIONS Since ASI 306 is a neutral cure system, no acetic acid is released during cure. However, on direct contact, uncured sealant will irritate eyes. Flush well with water and call physician if irritation persists. Avoid prolonged skin contact.STORAGE ASI 306, when stored in original, unopened container at or below 32°C (90°F), has a shelf life of 12 months from date of shipment.PACKAGING ASI 306 is supplied in (10.2 fl. oz.) caulking cartridge, (40 lb.) pail and (440 lb.) drum.WARRANTY AND LIMITATION ASI 306 warrants only that its products will meet its specifications. ASI shall in no event be liable for incidental or consequential damages. Except as expressly stipulated, ASI’s liability, expressed or implied, is limited to the stated selling price of any defective goods.
Underwriters Laboratories File E209770General Description of Material:100% silicone sealant furnished in the form of cartridges.Material Modifications - There shall be no changes in the formulation or composition of the material unless previously cleared through Underwriters Laboratories Inc.Form of Shipment - The materials are produced and shipped as finished products. |
Email us for information |